Apa Rated Sheathing 40 20 Exposure 1

The letter X means the glue of the plywood is exterior glue. CDX plywood is durable and moisture proof.


Exposure 1 Sheathing Plywood Plywood The Home Depot

Do not use on roofs.

. 979 368 201 98 48 39 34 25 390 147 50. When panels are applied vertically OSB or 5. LP WeatherLogic Struct I Rated Sheathing is Ideal for Strong and Stiff Roofing and Walls.

No Additional Features 1 Span Rating. Ad Proven to Seal Out Moisture Air LP WeatherLogic Panels Also Add Structural Stability. For vertical application use minimum 1532-inch APA Rated Sheathing 3216 Exposure 1 for studs spaced 16 inches oc or 1932-inch APA Rated Sheathing 4020 Exposure 1 for studs spaced 24 inches oc.

PRP-108 HUD-UM-40 1532 CATEGORY 000 RATED SIDING 24oc SIZED FOR SPACING EXTERIOR THICKNESS 0451 IN. Live Load Thickness Span Rating for Roofs lbs 38 240 30 716 2416 40 1532 3216 70 12 3216 70 1932 4020 130 2332 4824 175 1-18 48 oc 290 Live load for 24 oc span conditions. The recommendations for roof sheathing in Table 30 apply to APA RATED SHEATHING Exposure 1 or Exterior APA.

Rated OSB Sheathing Roof Panels APA Span Ratings APA Max. Exposure 1 rated sheathings either OSB or Plywood have a fully waterproof bond and are designed for applications where construction delays may be expected prior to providing protection. Floor sheathing shall be APA rated 34 thick minimum C-D Tongue Grove nailed to floor joists with 8d common nails 6 OC.

Philips Bugle-Head Coarse Thread Sharp Point Polymer Coated Exterior Screw 1 lbPack 947. Adhesive Bond Classification 5. Get the latest information on APA member products locate a member manufacturer near you and download publications from the APA products section.

4020 Structural 1 Rated. Over 95 of structural-use panels are rated as. Exposure 1 rated sheathings are made with the same exterior adhesives used in Exterior rated sheathings.

APA Rated Sheathing is rated for use as subfloor wall or roof sheathing. APA Rated Sheathing panels are not manufactured with smoothness or appearance in mind but offer strength suitable for most industrial applications. Exposure 1 Bond Classification 0451 in Thickness 1932 Performance Category APA Rated Sheathing 4020 Span Rating Exposure 1 Bond Classification 0578 in Thickness.

RTD Sheathing Syp. RATED SHEATHING 3216 SIZED FOR SPACING EXPOSURE 1 THICKNESS 0451 IN. 58 Deflection L600 L720.

Floor Span Rating must equal or exceed joist spacing. Use minimum 1932 inch APA Rated Sheathing 4020 Exposure 1 for studs spaced 24-inches oc. Learn more about APA Member Products.

4 rows APA Rated OSB Sheathing Roof Panels Performance Category APA Span Rating Allowable Live. Standard for APA Rated Sheathing Panels 13 Exposure Durability Classification 131 Exterior Exterior panels have bond durability suitable for applications permanently exposed to the weather. 489 184 101 49 24 19 195 73 587 221 121 59 29 23 21 234 88.

Bulk Pricing 1 Top Rated. Edges of wood structural panel roof sheathing supported at 24 inches on center shall be supported with blocking or edge clips. Uniform load deflection limits are 1180 of span under live load plus dead load and 1240 under live load.

The APA trademark is still the premier mark of quality. 240 span rated ZIP System Sheathing shall be used in wall applications ONLY. Moreover is CDX plywood APA rated.

Alternate for APA Exposure 1 rated sheathing. STRUCTURAL I RATED SHEATHING Exposure 1 or Exterior and APA RATED STURD-I-FLOOR Exposure 1 or Exterior. FMinimum Performance Category 1932 APA Sturd-I-Floor or APA Rated Sheathing for joist spaced 16.

The PERF CAT refers to the panel thickness or Performance Category. 132 Exposure 1 Exposure 1 panels may be used for appli-cations not permanently exposed to the weather. S t sg ny s i f oo r For guaranteed or warranted roofs contact membrane manufacturer for acceptable deck.

1532 PERF CAT APA Rated Sheathing 3216 Exposure 1. APA RATED SHEATHING 2416 716 INCH SIZED FOR SPACING. 10lb psf dead load assumed.

At edges 12 OC. Exposure 1 rated sheathings either OSB or Plywood have a fully waterproof bond and are designed for applications where construction delays may be expected prior to providing protection. CDX plywood is used as flooring materials wall sheathing roofing ply.

C-D Exposure 1 APA Rated Plywood Sheathing sometimes called CDX in the trade is occasionally mistaken as an Exterior panel and erroneously used in applications for which it does not possess the required resistance to weather. CDX stands for C-D Exposure 1 plywood. Typical apa trademarks rated sturd-i-floor 000 ps 1-83 underlayment prp-108 apa 24 oc 2332 inch sized for spacing tg net width 47-12 exposure 1 rated sheathing 3216 000 prp-108 hud-um-40c apa 1532 inch sized for spacing exposure 1 000 ps 1-83 fha-um-64 prp-108 apa sized for spacing exterior rated siding 303-18-sw 1132 inch 24 oc group 1 panel grade span rating thickness mill.

APA RATED SHEATHING 1532 3216 24 1 1932 4020 32 1 2332 4824 48 2 78 6032 60 2 APA RATED STURD-I-FLOOR 1932 20 oc 24 1 2332 24 oc 32 1 78 32 oc 48 2 a. 4020 L360 L240 L180 Bending Shear 1088 1631 2175 521 467 409 614 818 293 338 224 336 448 203. Tables 1 and 2 are generated assuming dry conditions normal duration of load and untreated Exposure 1 structural pan-.

Category 1932 plywood APA Rated Sturd-I-Floorc 20 oc Exposure 1 for joists spaced 16 inches oc. 734 276 151 73 36 29 26 14 292 110 37. Exposure 1 rated sheathings are made with the same exterior adhesives used in Exterior rated sheathings.

However because other compositional factors may affect bond. When panels are applied vertically OSB or 5-ply 5-layer plywood is recommended. PLEASE CALL FOR AVAILABILITY - 817-831-4206.

Rated Sheathing 1 Wood Species. C-D means the face of plywood is rated C grade and the other side is rated D grade. Post and Lamp Sets.

Hi-Bor APA-Rated Sheathing Pressure-Treated Plywood Grip-Rite 8x 1-58 in. APA Rated Sheathing Exposure 1 plywood commonly called CDX in the trade is sometimes. IndoorOutdoor 40 Watts LED Light Bulbs.

Rated Sheathing - Unsanded Southern Yellow Pine 1932 - 48x96 - 4020 Span Rating. APA recommends leaving a 18-inch space at panel edge and end joints unless otherwise recommended by the panel manufacturer. Low slope roofs are applicable to built-up single-ply and modified bitumen me.

Through 2c apply to APA Rated OSB Sheathing APA Rated OSB Structural I Sheathing and APA Rated OSB Sturd-I-Floor. APA Rated Sheathing 2. TG edges 51 Sample Specification APA Rated Sheathing 1532 Performance Category 3216 Exposure 1 Note.

3216 1 Exposure Durability. TABLE 30 RECOMMENDED UNIFORM ROOF. Douglas Fir 1 Pine 1 Plywood Features.

000 PRP-108 HUD-UM-40 1532 CATEGORY RATED STURD-I-FLOOR 24oc SIZED FOR SPACING. Interior 5 Exterior 3 Exposure 1 2 Savings Center.


Rated Sheathing 19 32 In Apa Southern Yellow Pine Syp Rated Sheathing Softwood Plywood Plywood Company Texas


Plywood Roof Sheathing Panels Gp Plytanium Plywood Sheathing


Apa Trademark Apa The Engineered Wood Association